DXH Series Hydraulic Motor Air Cooler

The explosion-proof air cooler fan adopts explosion-proof motor, explosion-proof marks: ExdⅠMb(YB3/YBK3), ExdⅡBT4Gb,ExdⅡCT4Gb,Extdb21Db, rated voltage: AC380/440/660V, high strength, optimized structure, small windshield area,minimize the wind resistance pressure and noise of the air outlet ensure sufficient heat exchange. The heat exchange area per unit volume of the radiator core is large, and the heat exchange effect is high. The core body and fan with high heat exchange efficiency are designed to be compact in structure, easy to install and maintain.

Products Details

The cooler, through vacuum brazing process, is driving by two-way gear hydraulic motor and high-strength fan blades to achieve stable cooling effect. High performance hydraulic motor can continuously keep running under complex working conditions. · Temperature controller can be selected. · A variety of pressure protection forms can be selected. · The oil inlet and outlet of the cooler are standard G thread, also can be customized or connected with SAE flange as required. · Equipped with hydraulic motor · Suitable for mobile machinery at outdoors · Suitable for pump truck It is composed of hydraulic motor,high strength fan blades and tightly structured high efficiency fin. With high performance hydraulic motor,it can operate for a long run-on period continuously under complex working conditions,and it can be maintained with low operation cost easily.
Model DXH-3 DXH-4 DXH-5 DXH-6 DXH-7 DXH-8 DXH-9 DXH-10 DXH-11 DXH-12 DXH-13 DXH-14 DXH-15
Cooling Capacity* (kW) 12 18 25 35 50 65 80 100 120 140 170 220 260
Rated Flow (L/min) 100 150 200 250 300 350 400 500 600 700 800 900 1000
Max.Working Pressure (bar) 20 20 20 20 20 20 20 20 20 16 16 16 16
Motor Displacement ***(ml/rev) 6 10 10 16 16 20 20 25 25 20*2 20*2 25*2 25*2
Max.Motor Pressure (Mpa) 21 21 21 16 16 20 20 25 25 20*2 20*2 25*2 25*2
Max.Motor Speed (r/min) 3000 3000 3000 3000 3000 3000 3000 2600 2600 3000 3000 2600 2600
Motor Inlet&Outlet Thread M22*1.5 M22*1.5 M22*1.5 M22*1.5 M22*1.5 M22*1.5 M22*1.5 SAE-CFlange SAE-CFlange M22*1.5 M22*1.5 SAE-CFlange SAE-CFlange
Motor Drain Thread  G1¼''  G1¼''  G1¼''  G1¼''  G1¼''  G1¼''  G1¼'' M22*1.5 M22*1.5  G1¼''  G1¼'' M22*1.5 M22*1.5
Inlet&Outlet Thread  G1''  G1¼''  G1¼''  G1¼''  G1¼''  G1½''  G1½''  G1½''  G1½''  G2''  G2''  G2''  G2''
Thermometric Thread   G3/8''   G3/8''   G3/8''   G3/8''   G3/8''   G3/8''   G3/8''   G3/8''   G3/8''   G3/8''   G3/8''   G3/8''   G3/8''
Noise Level**                 (dB) 65 65 68 70 74 80 84 87 92 94 84 86 90
A (mm±5) 427 532 587 632 632 752 837 972 1082 1442 1642 1842 2047
B (mm±5) 503 563 603 623 623 763 919 1059 1208 763 913 1043 1193
C (mm±2) 350 350 350 450 450 450 500 600 600 450 500 600 600
D (mm±2) 290 390 450 490 490 560 645 700 700 560 645 700 800
E (mm±2) 310 310 310 400 400 400 450 550 550 400 450 550 550
F (mm±5) 384 434 475 495 495 634 780 920 1070 600 760 900 1050
G (mm±5) 50 55 55 55 55 55 60 60 60 75 70 65 65
L (mm±2) 40 40 40 45 45 45 55 55 55 45 55 55 55
M (mm±2) 12*18 12*18 12*18 12*18 12*18 14*22 14*22 18*25 18*25 14*22 14*22 18*25 18*25
W1 180 200 220 250 280 320 380 400 500 320 380 400 500
W2 380 400 450 500 550 650 750 800 1000 650 750 800 1000
Note:   * Cooling capacity: cooling power at △T=40℃.              ** The noise value is measured at a distance of 1m from the cooler, which is only for reference.                   Because it is affected by the surrounding environment, medium viscosity and reflection.             *** Displacement of hydraulic motor: It can be adjusted appropriately according to the requirements of working conditions.                  (If necessary, please contact DONGXU service team)                   Hydraulic Motor Flow [l/min] Q=Vg*n/1000/η . In Q,Vg=Displacement of hydraulic motor[ml/r]; N=Fan Speed [rpm]; η=Volumetric Efficiency of Hydraulic Motor 90%,(Working pressure is 150bar)            ****DXH series can apply in occasion of explosion proof and requiring corrosion protection in harsh environment. (If necessary, please contact DONGXU service team)

Lifting vehicles

Garbage trucks

DXH 8 N C X O O
Cooler Type: Hydraulic Motor Driven Series Plate Size: 3/4/5/6/7/8/9/10/11/12/13/14/15 Bypass Valve: N=Build-in⬅Standard W=External M=Without Bypass Valve Oil Hole Direction: C=Side in side out⬅Standard S=Up in up out Wind Direction: X=Suction⬅Standard C=Blowing Temp. Controller: O=Without controller⬅Standard T=Temp. Switches--Action Temp.:     T50=50℃,T60=60℃,T70=70℃ C=Temp. Transmitter--     C1=Compact,C2=Digital Heatsink Protection: O=Without protection⬅Standard S=Anti-Stone net

Coal mining machinery

Hydraulic system circuit, independent cooling circuit and lubricating oil cooling system. For examples, coal mining machinery,mining machinery,hydraulic machinery,oil and gas power station,natural gas station,ship machinery,tunnel machinery,gear oil tank, and so on.

Mining vehicles

Metallurgical equipment

Port machinery

Snow sweepers

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours